Controllers

Our offer includes dedicated controllers for individual series of devices. Thanks to their implementation, device control becomes not only effective in the context of conscious system management, but above all convenient and simple.

3-step controller with thermostat HC3S

The controller is used to control devices equipped with three-speed fan motors. It has a three-stage speed control, and the built-in thermostat allows you to turn off the device after reaching the set temperature. Additionally, the controller controls the operation of actuators installed on the control valve. It is possible to work in both heating and cooling mode.

Power / Frequency: 230V AC / 50 ~ 60Hz

Maximum current: 3 A.

Control range: 10 ° C ~ 30 ° C

Operating mode: continuous or thermostatic

Regulation accuracy: <1 ° C

Housing protection degree: IP 30

Dimensions: 130 x 85 x 40 mm

Weight: 210 g

Fan speed controller HC

The HC speed controller is designed for voltage regulation of the fan motor operation. They are used in industrial air supply and heating systems. It comes in several variants. The choice of the appropriate version depends on the number of devices to be connected to one controller – the total intensity of the connected devices cannot exceed the maximum current flowing through the controller.

5-step adjustment: 80-105-135-170-230 V *
* for a 3 A regulator, regulation: 70-85-105-145-230 V

Power / Frequency: 230 V AC / 50-60 Hz

Maximum current (depending on version): 1.2 A, 3 A, 5 A, 7 A, 14 A

Working conditions: 0 ° – 40 ° C

Enclosure with protection degree: IP 54

Protection: thermal switch

Dimensions (depending on version): 90 x 173 x 89 mm / 123 x 240 x 125 mm / 146 x 272 x 138 mm

Weight (depending on the version): 1.45 kg, 2.5 kg, 4.5 kg, 5.5 kg, 10.5 kg

Thyristor speed controller

The TRO speed controller is designed to regulate the operation of the fan driven by an AC motor. Built on the basis of elements from the thyristor family, it allows for smooth adjustment of the engine speed.
We offer two models TRO-150W and TRO-600W.

Zasilanie/Częstotliwość: 220 ~ 240 V / 50 ~ 60 Hz

Maksymalne obciążenie:

  • 150 W dla modelu TRO-150W
  • 600 W dla modelu TRO-600W

Materiał obudowy: ABS (ognioodporny)

Wymiary:

  • Wymiary (TRO-150W): 86 x 86 x 42 mm
  • Wymiary (TRO-600W): 86 x 86 x 40 mm
thiristor
Thyristor speed controller

Programmable controller HMI

The controller is used to control the operation of devices equipped with three-speed fan motors. The controller automatically controls the operation of the device in accordance with a preset program (required air temperature). Possibility to connect an external temperature sensor (included). The device additionally controls the operation of actuators installed on the control valve. It has the MODBUS communication protocol, which enables the controller to be integrated with the building management system BMS.

Power / Frequency: 230V AC / 50-60Hz

Maximum current: 5 A

Working conditions: 0 ° -45 ° C

Regulation range: 5 ° -35 ° C

Regulation accuracy: +/- 0.5 ° C

External temperature sensor: NTC 10K

Data Transmission Standard (BMS): RS485

Enclosure with protection degree: IP 20

Dimensions: 86 x 86 x 13.3 mm

Weight: 0.27 kg

Programmable controller HMI EC

The controller is used to control the operation of devices equipped with EC motors. The controller automatically controls the operation of the device in accordance with a preset program (required air temperature). Possibility to connect an external temperature sensor (included). The device additionally controls the operation of actuators installed on the control valve. It has the MODBUS communication protocol, which enables the controller to be integrated with the building management system BMS.

Output signal: 0-10V

Power / Frequency: 230V AC / 50-60Hz

Maximum current: 5 A.

Working conditions: 0 ° -45 ° C

Regulation range: 5 ° -35 ° C

Regulation accuracy: +/- 0.5 ° C

External temperature sensor: NTC 10K

Data Transmission Standard (BMS): RS485

Enclosure with protection degree: IP 20

Dimensions: 86 x 86 x 13.3 mm

Weight: 0.27 kg

Programmable controller HMI SINGLE

The controller is used to control the operation of devices equipped with single-speed motors. It has many functions, incl. operation in heating, cooling or mixed mode, programmable mode, valve operation control, automatic fan speed selection. Included with the device is an external sensor, which allows you to read the temperature in the required place, even distant from the controller. In addition, the device can work in one of two modes – thermostatic or temperature difference. The latter enables effective control of the operation of destratificators. The device can be integrated with a BMS building control system (using the MODBUS communication protocol).

Power / Frequency: 230V AC / 50-60Hz
Maximum current: 5 A.
Working conditions: 0 ° -45 ° C
Regulation range: 5 ° -35 ° C
Regulation accuracy: +/- 0.5 ° C
External temperature sensor: NTC 10K
Data Transmission Standard (BMS): RS485
Enclosure with protection degree: IP 20
Dimensions: 86 x 86 x 13.3 mm
Weight: 0.27 kg

Programmable controller HMI CURTAIN

It is used to regulate the operation of HUMMER curtains, equipped with three-speed fans. It is an advanced driver with many functions, including operation in thermostatic mode (heating or cooling) or in relation to the door sensor, valve operation control, fan speed selection. It is also possible to integrate the device with a building control system type BMS (using the MODBUS communication protocol). The device can be integrated with a building control system type BMS (using the MODBUS communication protocol).

Power / Frequency: 230V AC / 50-60Hz
Maximum current: 5 A.
Working conditions: 0 ° -45 ° C
Regulation range: 5 ° -35 ° C
Regulation accuracy: +/- 0.5 ° C
External temperature sensor: NTC 10K
Data Transmission Standard (BMS): RS485
Enclosure with protection degree: IP 20
Dimensions: 86 x 86 x 13.3 mm
Weight: 0.27 kg

Programmable controller HMI WiFi

It is used to control the operation of a three-speed fan and the on/off valve actuator based on the difference between the temperature set on the device and the temperature measured in the room. The controller enables operation in heating, cooling or ventilation mode. The device has an intuitive touch-controlled LCD display. The controller connects to a dedicated application through which you can control the device from your own smartphone.

 

Sensor: NTC 10k

Accuracy: ±0.5°C

Temperature range: 5 -35°C

Power consumption: < 1.5W

Sync error: < 1%

Power supply: 95~240VAC, 50~60Hz

Maximum load: 5A (fan); 3A (valve)

Housing material: PC + ABS (fire retardant)

Dimensions: 88x88x42mm

Ambient conditions: t = 0 -45°C, ϕ = 5-95%

Degree of protection: housing -IP20; outdoor sensor-IP68

Manual room thermostat HC

The manual HC thermostat controls the operation of the heater. It automatically turns off the device after reaching the set temperature.

Power / Frequency: 230 V AC / 50-60 Hz

Maximum current: 3 A.

Working range: 0-40ºC

Adjustment range: 10-30ºC

Setting accuracy: <1ºC

Enclosure with protection degree: IP 30

Dimensions: 83 x 83 x 38 mm

Weight: 0.1 kg

Potentiometer EC

The EC potentiometer allows you to control the EC motors with a 0-10V control signal. A convenient knob is used for this, which allows you to adjust the fan efficiency in the range of 0-100%. The potentiometer also has an additional switching contact that cuts off the voltage from the fans when there is no need for their operation.

Output signal: 0-10V

Power supply: 10 – 12 V DC / 1 mA

Impedance: 10 kΩ + – 20%

Maximum switching contact load: 3 A / 230 V AC or 3 A / 12 V DC

Enclosure with protection degree: IP 54

Dimensions: 67 x 126 x 70 mm

Weight: 0.35 kg

Magnetic door sensor

The door sensor ensures that the device is activated when the door is opened. For this reason, it is widely used, among others. together with air curtains mounted above the entrance door, which is a condition for the proper performance of these devices. The magnetic door sensor is included with the AERIS E-1P, AERIS EN-1P, AERIS EN-3P and AERIS C-1P series curtains.

Mechanical door switch

The door sensor ensures that the device is activated when the door is opened. For this reason, it is widely used, among others. together with air curtains mounted above the entrance door, which is a condition for the proper performance of these devices. The mechanical door sensor is included with the AERIS WN-1P and AERIS EN-3P curtains for the thermostat.

HUMMER door sensor

The door sensor ensures that the device switches on when the door or gate is opened. For this reason, it is widely used, among others. together with HUMMER industrial curtains, mounted above the entrance gates, which is a condition for the proper performance of the functions of these devices.

Relay module RM-16A

It allows you to connect a receiver that draws a current with a higher intensity than it would result from the permitted load capacity of the regulator used. The maximum current consumption of the receiver cannot exceed 16 A.

Power supply / Frequency: 230V AC / 50-60 Hz

Maximum current: 16 A.

Inputs: NO / COM voltage free, SL voltage

Output signal: NO / COM / NC relay

Dimensions: 47 x 47 x 20 mm

STANDARD intelligent control panel

The STANDARD control panel has a liquid crystal LCD screen.
The controller comes with a 5 m long cable that can be extended if necessary. Suitable for work with INSPIRO recuperators. The control panel is sold in a set with a recuperator.

Intelligent PREMIUM control panel

The PREMIUM control panel has a liquid crystal LCD screen with touch buttons. The contemporary design of the device makes it look aesthetically pleasing in any interior. The controller comes with a 5 m long cable that can be extended if necessary. It is designed to control INSPIRO recuperators. The panel enables the cooperation of the recuperator with a humidity sensor.

Intelligent control panel VERTIC

The intelligent VERTIC touch control panel allows you to control the operation of the VERTIC series recuperator without the need to use the controller built into the device. The panel has an LCD display with touch buttons. The modern design of the device makes it look aesthetically pleasing and fit into any interior. The control panel allows you to modify and define all device parameters and accessories assigned to it.

Sensor CO₂ VERTIC

The CO2 sensor is responsible for signaling the level of carbon dioxide. Connecting the sensor to the recuperator allows the CO2 concentration to be kept below the level set by the user. It is suitable for work with VERTIC recuperators.

Sensor CO₂INSPIRO

CO₂ concentration sensor. It is suitable for use with INSPIRO recuperators. Connecting the sensor to the recuperator enables the CO₂ concentration to be kept below the level set by the user.

Humidity sensor

Relative humidity sensor. It is suitable for use with INSPIRO recuperators. Connecting the sensor to the recuperator allows to maintain the humidity level below the level set by the user. In order to integrate the sensor with the recuperator, it is necessary to use an intelligent PREMIUM control panel.

Two-way valve with HC 3/4 “actuator

A two-way valve with an actuator regulates the operation of the heater by closing / opening the circuit of the working medium.

Power supply / Frequency: 230 V AC / 50 – 60 Hz

Power consumption: 2 VA

Valve Kvs value: 6.3 m³ / h

Adjustment stroke: 3 mm

The working conditions of the actuator: -5ºC – 60ºC

Opening time: 3 – 5 min

Housing protection class: IP 54

Three-way valve with HC 3/4 ″ actuator

A three-way valve with an actuator regulates the operation of the device by closing / opening individual sections of the working medium circuit. The device is part of the basic KHC automation set dedicated to mixing chambers.

Power supply / Frequency: 230 V AC / 50 – 60 Hz

Power consumption: 7 VA

Valve Kvs value: 6.5 m³ / h

Actuator working conditions: 0 – 60 ° C

Opening time (engine): 18 s

Closing time (spring return): 5 s

Housing protection degree: IP 20

3-way valve with CV 3-point actuator

A three-way valve with an actuator regulates the operation of the device by closing / opening individual sections of the working medium circuit. The three-point actuator enables partial closing / opening of the valve.

Power / Frequency: 230 V AC / 50-60 Hz

Rated power: 2 VA

Valve Kvs value: 6.3 m³ / h

Working conditions: -20 -50 ° C

Movement time: 70… 90 s

Torque: 5 Nm

Housing protection class: IP 54

Mixing chamber controller

The mixing chamber controller is responsible for the precise operation of the heating and ventilation device, consisting of the MC series mixing chamber, HC series heater and STORM series roof fan (optional). The device is part of the basic KHC automation set dedicated to mixing chambers.

Zadajnik z wyświetlaczem LCD

The adjuster with display is used for communication with the mixing chamber controller. It is suitable for wall mounting as well as in an installation box. The device has a built-in temperature sensor.

Supply voltage: 24 V AC / DC

Display: 320 x 240 px

Data Emission Standard (BMS): RS485

Enclosure with protection degree: IP 30

Dimensions: 86 x 86 x 16 mm

Weight: 0.25 kg

0-10V damper actuator with spring return

The actuator enables automatic control of the air and mixing chamber dampers, which adapt the degree of air mixing to the current needs. The device is part of the basic KHC automation set dedicated to mixing chambers.

Power / Frequency: AC / DC 24 V 50/60 Hz

Working conditions: -30 – 50 ° C

Motor movement (time / revolution): 150 s / 90 °

Housing protection class: IP 54

Dimensions: 181 x 98 x 82 mm

Weight: 1.6 kg

Capillary thermostat

The capillary thermostat is an element of the mixing chamber frost protection. It controls the air temperature after the heater and signals its drop below a certain value. The device is part of the basic KHC automation set dedicated to mixing chambers.

Working conditions: -40-65 ° C

Setting range: -30-15 ° C

Capillary length: 2 m

Weight: 0.6 kg

Temperature sensor kit

Four temperature sensors adapted for installation behind the heater, on the return, indoors and outdoors. They provide the necessary information to the chamber controller, which controls the operation of the device on their basis. The device is part of the basic KHC automation set dedicated to mixing chambers.

Room temperature sensor

External temperature sensor

DFS differential pressure switch

Differential pressure sensor with relay. It informs about the increase in flow resistance on the filter and the necessity to replace it.

Working conditions: -20 – 60 ° C

Measurement range: 30 -500 Pa

Housing protection class: IP 54

Dimensions: 86 mm x 86 mm x 13.3 mm

Weight: 0.15 kg

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Ethernet EC card

The Ethernet card is a dedicated module that allows you to control the operation of the mixing chamber via a computer or Wi-Fi network.