Air water gate curtain HUMMER series
The HUMMER door air curtain is available in two variants. The water air curtain has a 1-row heat exchanger that heats the air flowing through it. The air curtain is cold but blows air at the temperature of the room. Both curtains are perfect for loading and unloading transports, creating a kind of air barrier when the entrance gate is opened. The main function of the gate curtain is to protect the object against the escape / inflow of air of undesirable temperature.
Description: Air water gate curtain HUMMER series
Place to use
The air curtain is designed for installation at industrial doors in places such as:
- warehouses,
- logistics centers,
- garages,
- car repair shops.
Parameters
Power range: 27.9 – 34 kW
Range: 7 m
Weight: 40 – 70 kg
Housing: powder coated galvanized steel
Additional information:
- Water curtains have a 1-row heat exchanger,
- Fans are devices with IP 54 protection and meet the requirements of the European Directive 2009/125 / EC (ErP 2015).
Control
HUMMER air curtains have dedicated accessories to automate the operation of the device. The use of appropriate automation makes it possible to program the curtain to adjust its operation to specific needs.
Benefits
- mounting elements included,
- effective protection against heat loss,
- durable housing,
- two coatings protecting the device against corrosion,
- easy assembly,
- modern design of the device.
Technical specification
HUMMER 150W-1P |
HUMMER 200W-1P |
HUMMER 150W-1P 2R |
HUMMER 200W-1P 2R |
HUMMER 150W-EC |
HUMMER 200W-EC |
HUMMER 150W-EC 2R |
HUMMER 200W-1P EC 2R |
|
---|---|---|---|---|---|---|---|---|
Product code | ACH150W-2001 | ACH200W-2002 | ACH150W2R-2304 | ACH200W2R-2305 | ACH150W-EC-2355 | ACH150W-EC-2356 | ACH150W-EC2R-2357 | ACH200W-EC2R-2358 |
Nominal heating capacity [kW] III stage*/II stage/ I stage |
30,8 / 26,0 / 22,8 | 37,6 / 31,4 / 28,4 | 74,0 / 67,8 / 57,1 | 89,1 / 80,3 / 70,7 | 35,1 | 42,8 | 77,4 | 89,9 |
Heating capacity range [kW]*** | 3,9 - 40,5 | 4,2 - 52,4 | 8,9 - 97,6 | 11,5 - 117,4 | 4,04 - 46,3 | 5,42 - 56,3 | 8,3 - 102,2 | 10,1 - 118,5 |
Maximum airflow [m3/h] III stage*/II stage/I stage |
6500 / 5500 / 4000 | 8500 / 7000 / 5500 | 8700 / 7350 / 5350 | 11000 / 9000 / 7100 | 9500 | 12400 | 8900 | 11200 |
Maximum range [m] III stage*/II stage/I stage |
6,5 / 6,0 / 5,5 | 7,0 / 6,5 / 6,0 | 7,0 / 6,5 / 6,0 | 7,5 / 7,0 / 6,5 | 7,0 | 7,5 | 7,0 | 7,5 |
Number of rows [pcs.] | 1 | 1 | 2 | 2 | 1 | 1 | 2 | 2 |
Capacity of water [dm³] | 2,31 | 3,02 | 4,35 | 5,75 | 2,31 | 3,02 | 4,35 | 5,75 |
Maximum temperature of working fluid [°C] | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
Maximum working pressure [MPa] | 1,6 | 1,6 | 1,6 | 1,6 | 1,6 | 1,6 | 1,6 | 1,6 |
Connection diameter ["] | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 | 3/4 |
Supply voltage/Supply frequency [V/Hz] | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
Nominal motor current [A] III stage*/II stage/I stage |
2,16 / 1,72 / 1,40 | 3,24 / 2,58 / 2,10 | 4,10 / 3,30 / 2,80 | 6,15 / 4,95 / 4,20 | 5,90 | 8,85 | 5,90 | 8,85 |
Nominal motor speed [rpm] III stage*/II stage/I stage |
1360 / 1050 / 750 | 1360 / 1050 / 750 | 1380 / 1200 / 900 | 1380 / 1200 / 900 | 1400 | 1400 | 1400 | 1400 |
Nominal motor power [W] III stage*/II stage/I stage |
480 / 380 / 320 | 720 / 570 / 480 | 910 / 700 / 560 | 1365 / 1050 / 840 | 860 | 1290 | 860 | 1290 |
Protection degree IP [-] | 54 | 54 | 54 | 54 | 54 | 54 | 54 | 54 |
Net weight [kg] | 51 | 70 | 54 | 73 | 52 | 71 | 55 | 74 |
Noise [dB] | 66 | 69 | 65 | 68 | 66 | 69 | 65 | 68 |
** - for parameters 90/70°C and 0°C inlet air temperature
*** - for AC motor max. 120/90°C, 0°C inlet air temperature, III stage // min. 40/30°C, 20°C inlet air temperature, I stage; for EC motor max. 120/90°C, 0°C inlet air temperature with 100 % air expense // min. 40/30°C, 20°C inlet air temperature with 50 % air expense
**** - measurement at the distance 5 m
Files to download
Here you will find: user manuals, CE compliance declarations, product brochures, 3D models, and more.
If you can't find the file you're looking for in our library, please contact us. We'll be happy to help.
CALCULATOR REVENTON GROUP
How to select the power of heating devices?
- Calculating the thermal demand of a building
- Predefined parameters for specific regions
- Easy and user-friendly calculator interface
- Automatic (approximate) selection of devices for thermal load
CONTACT AN ADVISOR
Do you want to join the group of 98% satisfied customers? Do you want to buy our products for further resale? Are you a designer? Installer? Do you want to establish a B2B cooperation on favorable terms?
Call or write us!
REQUEST A FREE QUOTE
Do you need perfectly tailored HVAC equipment for your facility? Trust our specialists! We offer:
- comprehensive evaluation tailored to your unique need
- fast order processing
- post-sales support and technical assistance
Contact us today, and our experts will gladly answer your questions and prepare a personalized offer tailored to your needs.
- We select HVAC devices that optimize the energy efficiency of your facility, bringing significant savings.
- Our HVAC solutions not only provide thermal comfort but also generate real financial savings by minimizing operating costs.
- We offer only the best devices, supported by a long-lasting warranty, providing peace of mind and investment certainty.
- Our team operates efficiently. Order an estimate now to start the journey towards an efficient and cost-effective system based on Reventon devices.