LPHW unit heaters
EFFICIENT HEATING AND COOLING SUPPORT FOR INDUSTRY AND AGRICULTURELPHW unit heaters are efficient devices for heating industrial, commercial and agricultural facilities. Depending on the series, they can operate with a central heating system, heat pumps or chilled water, providing efficient heating and cooling support. Our range also includes suitable components and accessories for unit heaters.
Choose your industrial LPHW unit heater variant
LPHW unit heater
HC Series
Universal solution for industrial and commercial facilities.
-
Housing:
EPP
-
Heating capacity:
1,5–92,7 kW
-
Cooling capacity:
1,9–35,0 kW
LPHW unit heater
FARMER Series
Solution for aggressive working environments. Resistant to ammonia, moisture, dust and acidic fumes.
-
Housing:
EPP / Laminate
-
Heating capacity:
3,9–83,9 kW
-
Cooling capacity:
6–22,7 kW
LPHW unit heater
S Series
Classic solution for industrial and commercial facilities.
-
Housing:
Galvanised steel
-
Heating capacity:
1,6–66,2 kW
-
Louvres:
Steel
Have additional questions?
Need technical support? Or would you like to ask about commercial terms? Call us or write to us!
Why choose our LPHW unit heaters?
Heat pump compatibility
LPHW unit heaters can be matched to installations with heat pumps and other low-temperature heat sources. The final capacity depends on the water parameters, room temperature and required airflow, which is why individual technical selection is recommended for such installations.
Selection for different types of facilities
Three product series make it easy to choose a unit for specific working conditions: HC for typical industrial and commercial facilities, FARMER for aggressive environments and S for applications requiring a steel construction.
Find out which series to choose and when
Meeting our clients' needs
|
If you are looking for a unit for: |
Select series |
Why? Key advantages |
|---|---|---|
| A production hall, warehouse, workshop or shop. | HC | This is the most versatile series, with 230 V, EC motor or 400 V variants. |
| A piggery, cowshed, poultry house, car wash, carpentry shop or wastewater treatment plant. | FARMER | The series is designed for environments with ammonia, moisture, dust and aggressive vapours. |
| A facility where a steel casing is a priority. | S | The S series offers a classic design with a steel casing. |
| An installation focused on precise control and lower electrical energy consumption. | HC-EC (within the HC series) | The EC motor enables smooth regulation and better operational adaptation of the unit. The final heating capacity depends on water parameters and operating conditions, so it is advisable to verify the selection. |
Use the
sizing calculator
The calculator has an easy, user-friendly interface and lets you:
- Calculate the heating demand of a building with different volumes
- Select predefined parameters for specific regions
- Select units based on heat load and size
Volume and temperature
Volume, insulation and expected indoor temperature.
Type and characteristics of the facility
Type of facility and its characteristic features.
Installation parameters
Water or heating medium parameters.
Which heat exchanger
in LPHW unit heaters
should you choose?
Copper and aluminium
heat exchanger
LPHW unit heaters use copper and aluminium heat exchangers, ensuring efficient heat transfer in both heating and cooling mode. Depending on the model, versions with a 1, 2, or 3-row heat exchanger are available. The unit can operate with a heating medium at a temperature of up to 120°C
- Housing: Copper + aluminium
- Protective coating: none
- Corrosion resistance: Standard
Heat exchanger with
GOLD epoxy coating in the FARMER series
The FARMER HCF is equipped with a copper and aluminium heat exchanger, protected by a GOLD epoxy coating that provides maximum corrosion resistance. This advanced solution protects the unit against the harmful effects of high humidity, ammonia and acidic fumes, ensuring long, reliable operation in demanding agricultural conditions.
- Housing: Copper + aluminium
- Protective coating: GOLD epoxy
- Corrosion resistance: High (fumes, moisture)
Did you know?
The FARMER OpenAir model has wider spacing between the exchanger fins, making it less prone to clogging and even easier to clean.
Properties of EPP and steel casings
Most of our LPHW unit heaters feature an EPP casing, while the dedicated S series has a steel one. Both stand out for their high quality and durability. The traditional steel casing performs excellently in demanding industrial conditions, while the EPP casing made of expanded polypropylene provides additional benefits.
| Properties |
EPP casing
|
Steel casing
|
|---|---|---|
| Material | Expanded polypropylene | Powder-coated galvanised steel |
| Sound damping | Dampens sound | Does not dampen sound |
| Weight | Lighter and 100% eco-friendly | Solid and heavier construction |
| Air louvres | Polypropylene | Steel |
| Resistance | Resistant to moisture and damage | Standard |
Did you know?
Opening laminate casing in the FARMER OpenAir model
As the only unit in our range, it has a casing made of laminate protected with a gelcoat finish, further reinforced with an aluminium frame. This unique solution was designed for extremely dusty environments. The nozzle is connected to the exchanger frame with hinges and latches, allowing the entire structure to be opened quickly for direct access to the interior for thorough, periodic cleaning.
FILES TO DOWNLOAD
Blog
Knowledge base
Guides, comparisons, analyses, reviews. Practical installation tips, product news and expert articles.
See moreLibraries
BIM and CAD
Professional 3D models, Revit libraries and DWG files. Essential tools for designing modern installations.
See moreTechnical
Documentation
Complete file library: installation manuals, data sheets, hygiene certificates and declarations of conformity.
See moreProduct
Catalogue
The latest Reventon Group product catalogue. A cross-section of the range broken down by category, series and model.
See the catalogueFAQ
This value depends on the operating time of the unit and the power of the electric motor used in the heater. For example, an LPHW unit heater with a 200 W motor will consume approximately 0.2 kWh of electrical energy during one hour of operation. On an annual basis, thanks to the advanced technology of EC motors, consumption can be lower when the unit is not operating at full speed.
Yes. Almost all our LPHW unit heater series (HC and FARMER) are adapted to operate with chilled water. However, it must be noted that in cooling mode, moisture condenses on the heat exchanger. Therefore, to ensure proper operation of the unit, we obligatorily recommend equipping it with a dedicated drip tray connected to the sewage system, regardless of the room type.
An EC motor should be considered when operating costs (ROI) are a priority. It offers smooth capacity regulation and consumes significantly less energy when operating at lower speeds than an AC induction motor. We recommend it for modern projects focused on the highest energy efficiency class in LPHW unit heaters.
Expanded polypropylene (EPP) is a lightweight material, resistant to deformation and highly effective at damping vibrations, which facilitates installation and reduces operational noise. A steel casing (S series) is, in turn, a heavier, traditional solution, chosen by customers accustomed to classic design and the strict standards of heavy industry.
For full flexibility, we recommend a rotary bracket. It enables horizontal rotation of the unit, which makes it easier to direct the airflow exactly where it is needed, and also significantly facilitates service work. This is complemented by flexible connection hoses, which make connection to the heating system easier.
In the case of ceiling installation, it is worth considering suspension brackets with shock absorbers.
The HC series includes lightweight units in an EPP casing and is the most versatile family for industrial and commercial facilities. The S series is based on a steel casing and is ideal where the user prefers a classic, solid design. Additionally, the air louvres in the HC series are made of ABS material, while in the S series they are made of steel.
The majority of our unit heaters (HC series and S series) are equipped with fans with an IP54 rating. They guarantee very good resistance to dust and moisture, entirely sufficient for safe operation in standard production halls, workshops and warehouses. For facilities with extreme dust levels and strict sanitary requirements, we have prepared fans with an increased IP66 rating (available in FARMER series models). This rating provides complete protection against dust ingress and resistance to direct contact with water. We encourage you to check the descriptions of specific product series to learn more details about dedicated fans.
LPHW unit heaters can be mounted on the wall or under the ceiling, saving space. For correct installation and the appropriate wiring diagram for the controller, we recommend consulting the instructions provided in the technical documentation.
Blog
LPHW unit heater and heat pump — how do they work together?
A unit heater and heat pump combination is something owners of industrial buildings ask about more and more often when they look...
Read more
Heat recovery ventilation in summer – facts, myths and practical tips
Does mechanical ventilation with heat recovery come in useful during summer heatwaves? Many people still believe that heat recovery is a system...
Read more
Heat recovery vs air conditioning – differences, similarities and why they make the perfect pairing
In modern, energy-efficient construction, the concepts of heat recovery ventilation and air conditioning frequently appear side by side, which often leads to...
Read moreBook a quick
consultation
Don't waste time analysing catalogues yourself. Leave your contact details — we'll call back to discuss your facility's parameters and prepare a specific solution. What do you gain from a single conversation?
-
Calculation of heating/cooling capacity requirements for your volume
-
Immediate confirmation of unit availability and realistic delivery time
-
Selection of units that will reduce electricity and heating bills, not just those with a low purchase price
-
Direct contact with an expert who will help with installation and design issues