The HC-3S LPHW unit heater is designed for industrial and commercial facilities such as production halls, warehouses, workshops, retail spaces and garages.

Heating capacity 1,55 – 91,5 kW
Cooling capacity 1,9 – 35,0 kW
Airflow 850 – 5000 m³/h
Housing EPP lekka · cicha · odporna

O produkcie

HC-3S 230 V is the most universal model in the HC series. Designed for industrial and commercial facilities — production halls, warehouses, workshops, commercial spaces, and garages.

It requires connection to a water system with a heating medium. It can also be supplied with cold water (chilled water) for air circulation and cooling in the facility. Fully compatible with heat pumps — both in heating and cooling modes.

The 3-speed fan control allows precise adjustment of the air flow to the needs of the facility and operating conditions. For projects requiring the highest energy efficiency, a version with an EC motor (stepless 0–100% control) is available.

Key features

  • EPP housing — lightweight, moisture-resistant, damps vibrations
  • Cu/Al exchanger in 1, 2, or 3-row versions
  • Heating mode and cooling support (chilled water)
  • 3-speed AC induction motor, protection rating IP54
  • ABS louvers — air flow direction adjustment
  • Compatible with heat pumps
  • Complies with Directive 2009/125/EC (ErP 2015)
  • 24-month manufacturer’s warranty

Lightweight and durable EPP housing

The HC-3S LPHW unit heater features a housing made of expanded polypropylene (EPP), a lightweight material resistant to mechanical damage that provides excellent thermal and acoustic insulation. This housing guarantees durability in demanding industrial environments and facilitates installation due to its low weight.

Copper and aluminum heat exchanger

The HC-3S series utilizes a copper and aluminum heat exchanger, ensuring efficient heat transfer in both heating and cooling modes. Depending on the model, versions with a 1, 2, or 3-row heat exchanger are available. The unit can operate with a heating medium temperature of up to 120°C.

Cooling mode and water vapor condensation

During operation in cooling mode, water vapor condensation may occur on the surface of the unit. For effective condensate drainage, it is recommended to use a dedicated drain pan.

The pan is compatible with wall mounting and should be connected to the sewage system for safe removal of the collected water.

3-speed AC induction motor

HC-3S LPHW unit heaters are equipped with an AC induction motor with 3-speed control and an IP54 protection rating.

For projects requiring higher energy efficiency, a version with an EC motor is available, offering stepless speed control in the 0–100% range and reduced energy consumption.

Adjustable louvers for precise air flow direction control

Every HC-3S LPHW unit heater is equipped with manually adjustable ABS louvers, enabling precise setting of the air flow direction. Depending on the requirements, it is possible to use a 360° diffuser or a confuser for even air distribution.

Quiet and compact HC15-3S heater

The HC15-3S is a quiet and compact unit, perfect for smaller spaces. The heater features an EPP housing, making it lightweight and easy to install. It ensures reliable operation and low energy consumption.

Dedicated HC rotating mounting bracket

The HC rotating bracket is a practical mounting element dedicated to the HC series LPHW unit heaters.

It enables easy horizontal rotation of the unit, allowing precise adjustment of the air flow direction to the current needs of users and the layout of the room.

The bracket also facilitates installation and servicing of the heater.

Do you have additional questions?

Do you need technical support? Or maybe you want to inquire about commercial terms? Call us or write to us!

Models and parameters

The HC-3S series includes 8 models from the compact HC15-3S to the high-performance HC80-3S. Output values are specified for the 3rd fan speed at standard water parameters of 80/60°C and an inlet air temperature of 0°C.

Parameter HC15-3S HC20-3S HC30-3S HC35-3S HC45-3S HC50-3S HC70-3S HC80-3S
Max heating output 23,3 28,4 34,9 40,1 55,6 65,8 80,1 91,5
3rd speed output (kW) 17,2 21,4 26,4 30,3 42,0 49,8 60,6 69,2
2nd speed output (kW) 13,4 17,3 20,3 22,9 28,9 45,2 40,1 61,5
1st speed output (kW) 12,1 13,3 15,5 17,3 21,1 34,6 32,7 46,5
Air flow 3rd speed (m³/h) 1500 3200 3100 2700 2500 5000 3400 4200
Air range (m) 10 19 18 15 14 24 18 21
Number of exchanger rows 2 1 1 2 2 2 3 3
Water capacity (dm³) 0,45 0,65 0,80 1,35 1,70 1,95 2,85 2,85
Motor power (W) 80 185 185 185 185 455 240 455
Noise level 3rd speed (dB) 53 57 57 56 56 66 58 65
Net weight (kg) 10,0 12,5 12,5 14,0 14,0 20,5 20,0 22,5

FAQ

This value depends on the operating time and the power of the electric motor used in the heater. For example, a water heater with a 200 W motor will consume approximately 0.2 kWh of electricity per hour of operation. On an annual basis, thanks to advanced EC motor technology, consumption can be lower when the unit is not running at full speed.

Yes. Almost all of our series of LPHW unit heaters (HC and FARMER) are adapted for operation with chilled water. However, keep in mind that moisture condensation occurs on the heat exchanger during cooling mode. Therefore, for proper operation, we mandatorily recommend equipping the unit with a dedicated drain pan connected to the sewage system, regardless of the room type.

An EC motor should be considered when operating costs (ROI) are a priority. It offers stepless performance control and consumes significantly less energy at lower speeds than an AC motor. We recommend it for modern projects that prioritize the highest energy efficiency class in water heaters.

Expanded polypropylene (EPP) is a lightweight material that is resistant to deformation and effectively damps vibrations, which facilitates installation and reduces operational noise. Steel housing (S series) is a heavier, traditional solution chosen by customers accustomed to classic design and the strict standards of heavy industry.

For full flexibility, we recommend the rotary bracket. It allows for horizontal rotation of the unit, which facilitates precise directing of the airflow exactly where it is needed, and also significantly eases maintenance work. It is also worth considering hangers with shock absorbers, connection hoses, and automation components (e.g., three-way valves to increase the response speed of the unit).

The HC series includes lightweight units in an EPP housing and is the most universal family for industrial and commercial facilities. The S series is based on a steel housing and works well where the user prefers a classic, solid construction. Additionally, air louvers in the HC series are made of ABS material, whereas in the S series, they are made of steel.

Most of our heaters (HC series and S series) are equipped with fans featuring an IP54 rating. They guarantee very good resistance to dust and moisture, which is completely sufficient for safe operation in standard production halls, workshops, and warehouses. For facilities with extreme dust levels and high sanitary requirements, we have prepared fans with an increased IP66 tightness class (available in models from the FARMER series). This class ensures complete protection against dust ingress and resistance to strong water jets, allowing, for example, safe cleaning of the unit under pressure. We encourage you to check the descriptions of specific product series to learn more details about the dedicated fans.

Water heaters can be wall-mounted or ceiling-mounted, saving space. For proper mounting and the appropriate wiring diagram for the controller, we recommend using the manual found in the technical documentation.

Request a quick

consultation

Don't waste time analyzing catalogues on your own. Leave your contact info — we will call you back to ask about your facility's parameters and prepare a specific solution. What do you gain from a single conversation?

  • Calculation of heating/cooling output requirements for your volume
  • Immediate confirmation of unit availability and real delivery time
  • Selection of equipment that lowers electricity and heating bills, rather than just costing less upfront
  • Direct contact with an expert who will assist with installation and design matters
Nie chcesz pisać? Zadzwoń! +48 33 500 08 88 [email protected]